Manifold Cabinets

Manifold cabinets house the control systems for underfloor heating distribution. Each cabinet contains a 12V power supply that powers controller boards (Kincony A8), which use dry relay contacts to switch 230V power to normally-open motorized valves.

Format: [FLOOR]M[NUMBER]

  • M = Manifold cabinet
  • Example: GM1 = Ground Manifold 1, BM1 = Basement Manifold 1, SM1 = Second floor Manifold 1

Format: [CABINET]-[ROOM]-[TYPE][ID]

  • Example: GM1-KT-FAN1 = Ground Manifold 1, Kitchen, Fan 1
  • Example: GM1-PSU1 = Ground Manifold 1, Power Supply 1
CodeDescription
PSUPower supply (12v/24v)
FANVentilation fan
CTRLController/relay board (e.g., Kincony A8)
VALVEMotorized valve (230V, normally open)
TEMPTemperature sensor (e.g., DS18B20)
SENSOROther sensors (water leak, etc.)

Motorized valves are 230V normally open - they allow heat circulation by default. In case of controller failure or power loss, the system defaults to a safe state with heat flowing through all zones.

Each manifold cabinet contains:

  1. 12V Power Supply - Powers the Kincony A8 controller
  2. Kincony A8 Controller - 8-relay board with:
    • Dry relay contacts (10A rated) switching 230V to valves
    • Digital inputs for DS18B20 temperature sensors
    • Digital inputs for water leak sensors
    • Network connectivity for home automation integration
Electrical Panel (230V) → Manifold PSU → 12V DC → Kincony A8
Valve Circuits (230V) → Dry Relay Contacts (10A) → Motorized Valves

Each manifold cabinet’s power supply is connected to a specific electrical circuit. The manifold component codes (e.g., GM1-KT-FAN1) reference low-voltage components, while their power source is documented in the electrical system (e.g., circuit G2-24 powers GM1-PSU1).

Note: The 230V valve circuits are separate from the 12V control circuits - the Kincony A8’s dry relay contacts provide galvanic isolation between control logic and valve power.

Code Description Location Floor Electrical Circuit Note
BM1 Basement manifold cabinet Basement technical room Basement - Future installation - not yet implemented
BM1-PSU1 Power supply - 12v / 5A - Future: Powers Kincony A8 controller
BM1-CTRL1 Controller - 12v - Future: 8-relay board for valve control, DS18B20 temp sensors, water sensors via digital inputs
GM1 Ground floor manifold - Kitchen area Kitchen manifold cabinet Ground G2-24 Main ground floor heating distribution
GM1-PSU1 Power supply - 12v - Powers Kincony A8 controller and ventilation fan
GM1-CTRL1 Controller - 12v GM1-PSU1 8-relay board (10A dry contacts) for 230V valve control. Monitors DS18B20 temp sensors and water sensors via digital inputs
GM1-KT-FAN1 Ventilation fan Kitchen 12v 200mm GM1-PSU1 Thermaltake CL-F015-PL20BL-A PURE fan - moves warm air from kitchen to other areas
SM1 Second floor manifold cabinet Second floor technical space Second - Future installation - not yet implemented
SM1-PSU1 Power supply - 12v - Future: Powers Kincony A8 controller
SM1-CTRL1 Controller - 12v - Future: 8-relay board for valve control, DS18B20 temp sensors, water sensors via digital inputs
  • Kitchen: Uses GM1 for heat distribution fan (GM1-KT-FAN1)
  • Electrical Circuits: See Ground Central 2 for power supply circuits