Basement central

  • Model: Harju/Famatel 3-rail IP65 (Motonet 90-01794)
  • Feed: 4mm² 5-wire from main central
  • Capacity: 3×20A (limited by feed wire)
  • Main breaker: 63A 4P (TODO: Replace with 3×20A to match feed)
  • RCCB protection: 2× 40A/30mA 4-pole
  • Circuit positions: 42 (14 per phase, using hexadecimal: B1-11 to B1-1E per rail)
  • Spare capacity: 10 additional modules

Protects general-use circuits on phases 1 and 2:

  • Wall sockets (zones 1 & 2)
  • Network cabinet
  • Dehumidifier

Protects specialized circuits on phases 2 and 3:

  • Dishwasher (future)
  • Manifold cabinet (Kincony)
  • Workshop sockets

Critical loads that bypass RCCB to prevent nuisance tripping:

  • Heat pump (3-phase: B1-11, B1-21, B1-31)
  • Basement lighting (B1-12)
  • Ventilation (B1-33)

Total basement area: 40m²

Permanent loads:

  • Heat pump: 3×16A (3-phase)
  • Dehumidifier: 330W (~1.5A)
  • Network cabinet: Router, PoE switch, AP, NAS (~2A)
  • Manifold cabinet: Kincony A4/A6 controller
  • Ventilation: Variable speed fan

Intermittent loads:

  • Power tools (workshop)
  • Dishwasher (future)
Code Description Location RCCB Fuse Phase TODO
B1-11 Heat pump - Phase 1 Basement no 16A 1
B1-12 Basement lighting Basement no 10A 1
B1-13 Wall sockets Basement - Zone 1 yes 16A 1
B1-14 Network cabinet Basement yes 10A 1
B1-15 Dehumidifier Basement yes 10A 1
B1-16 unwired - no - 1
B1-17 unwired - no - 1
B1-18 unwired - no - 1
B1-19 unwired - no - 1
B1-1A unwired - no - 1
B1-1B unwired - no - 1
B1-1C unwired - no - 1
B1-1D unwired - no - 1
B1-1E unwired - no - 1
B1-21 Heat pump - Phase 2 Basement no 16A 2
B1-22 Wall sockets Basement - Zone 2 yes 16A 2
B1-23 Dishwasher (future) Basement yes 16A 2 Install if needed
B1-24 Manifold cabinet (Kincony A4/A6) Basement - Manifold cabinet yes 10A 2
B1-25 unwired - no - 2
B1-26 unwired - no - 2
B1-27 unwired - no - 2
B1-28 unwired - no - 2
B1-29 unwired - no - 2
B1-2A unwired - no - 2
B1-2B unwired - no - 2
B1-2C unwired - no - 2
B1-2D unwired - no - 2
B1-2E unwired - no - 2
B1-31 Heat pump - Phase 3 Basement no 16A 3
B1-32 Workshop sockets Basement - Workshop area yes 16A 3
B1-33 Ventilation Basement no 10A 3
B1-34 unwired - no - 3
B1-35 unwired - no - 3
B1-36 unwired - no - 3
B1-37 unwired - no - 3
B1-38 unwired - no - 3
B1-39 unwired - no - 3
B1-3A unwired - no - 3
B1-3B unwired - no - 3
B1-3C unwired - no - 3
B1-3D unwired - no - 3
B1-3E unwired - no - 3